Flame Scanner Accessory Parts - Sets for ITS 184X0254M-Series

Compiled for your needs



The advantages of buying these sets are that all included parts fit seamlessly together. All the parts have been tested for daily use in the turbine environment. They come fully prepared with all the parts you need. You would therefore not have to think about ensuring that you have all the correct parts as it is already prepared and checked for you.

The five different package variations we will put together are as follows:

Set Protected Cable  ITS 184X0251M911  ⇨

Flame Scanner Set - Cable Protection  ITS 184X0251M921  ⇨

Flame Scanner Set - Water Cooling and Protection  ITS 184X0251M941  ⇨

Flame Scanner Set - Conversion and Protection  ITS 184X0251M961  ⇨

Flame Scanner Set - Conversion Premium (incl. Water Cooling and Cable Protection)  ITS 184X0251M981  ⇨

ITS 184X0251M911 - Set Protected Cable

Set Protected Cable ITS 184X0251M911 for ITS Flame Scanner 184X0254M-SeriesThere are many issues with the flame monitoring process which result from broken or abraded connection cables. Damages to the cable caused by vibrations or careless maintenance personnel can hamper the effectiveness and accuracy, or even the functionality of the flame scanning system and the safe operation of the gas turbine.

Therefore we have anticipated the needs of our customers by producing a more sophisticated alternative to the OEM Part. This part consists of a metal hose covering the cable from the Flame Scanner to the junction box.

With the 90° connector you can link the hose structure to the Flame Scanner easily. These pieces by ITS are made out of stainless steel, instantly increasing the sustainability of not only the tube type but also the cable which it protects. The plug is a part according MIL specification, the protective tube meets international industrial standards.

Depending on the manufacturer of the junction box, an adapter converting 3/8" to 1/2 ", 3/4" or 1 " may be necessary and is included in the set.

This set includes the following parts:

1x Stainless Steel 90° connector with cable  ITS 184X0251M421  ⇨

1x Spirally-wound metal protective conduit (3 Meter)  ITS 184X0251M461  ⇨

1x Fitting set (consisting of 2 parts)  ITS 184X0251M481  ⇨

1x Junction box fitting set  ITS 184X0251M482  ⇨

Documents

PDF Icon   Technical specification Protected Cable for Flame Scanner ITS 184X0251M911 (2 MB)

PDF Icon   ITS Flame Scanner Info Folder - High Resolution (8,9 MB)

PDF Icon   ITS Flame Scanner Info Folder - Low Resolution (0,9 MB)

Videos and Tutorials

Video Icon   Video Tutorial - How to install ITS 184X0251M911 Cable Protection on a Gas Turbine

Video Icon   Video Tutorial - How to assemble the Flame Scanner Cable Protection System ITS 184X0251M911

ITS 184X0251M921 Flame Scanner Set - Cable Protection

Set Protected Cable ITS 184X0251M911 and ITS Flame Scanner 184X0254M-SeriesThe constant deterioration of the cable from the vibrations created from the operation of the gas turbine or careless maintenance personnel, can cause repeated damage to the cable between the Flame Scanner and the junction box. With this set, the cable is reliably protected and future damages can be avoided.

The stainless steel hose is particularly advantageous as it protects the cable from the junction box to the flame scanner. By default, 3 meters are supplied, but can be ordered according to your needs. If you add that together with the connector and the fitting sets, an efficient protection of the cable is ensured.

Depending on the manufacturer of the junction box, an adapter converting 3/8" to 1/2 ", 3/4" or 1 " may be necessary and is included in the set.

This set comes complete with:

1x Stainless Steel 90° connector with cable  ITS 184X0251M421  ⇨

1x Spirally-wound metal protective conduit (3 Meter)  ITS 184X0251M461  ⇨

1x Fitting set (consisting of 2 parts)  ITS 184X0251M481  ⇨

1x Junction box fitting set  ITS 184X0251M482  ⇨

1x Flame Scanner  ITS 184X0254M029  ⇨

Video Icon   Video Tutorial - How to assemble the Flame Scanner Cable Protection System ITS 184X0251M911

ITS 184X0251M941 Flame Scanner Set - Water Cooling and Protection

ITS 184X0251M941 Flame Scanner Set - Water Cooling and Protection and ITS Flame Scanner 184X0254M-SeriesOur Water Cooling System is especially favorable as it ensures that the temperature within the surface of the Flame Scanner where the electronics are stored is kept cool enough for everything to stay fully operational for longer.

All of our products have been well tested in daily use with the gas turbine and its environment and in special accordance with our Flame Scanner ITS 184X0254M-Series.

Depending on the manufacturer of the junction box, an adapter converting 3/8" to 1/2 ", 3/4" or 1 " may be necessary and is included in the set.

This set includes:

1x Stainless Steel 90° connector with cable  ITS 184X0251M421  ⇨

1x Spirally-wound metal protective conduit (3 Meter)  ITS 184X0251M461  ⇨

1x Fitting set (consisting of 2 parts)  ITS 184X0251M481  ⇨

1x Junction box fitting set  ITS 184X0251M482  ⇨

1x Water Cooling Coil  ITS 184X0251M621  ⇨

1x Flame Scanner  ITS 184X0254M029  ⇨

Video Icon   Video Tutorial - How to assemble the Flame Scanner Cable Protection System ITS 184X0251M911

ITS 184X0251M961 Flame Scanner Set - Conversion

ITS 184X0251M961 Flame Scanner Set - Conversion and ITS Flame Scanner 184X0254M-SeriesThis set fits perfectly if you want to switch to a modern flame scanning technology and simultaneously increase the protection for the flame scanner cable.

The Conversion Module determines the signal provided by the Flame Scanner with a SiC photodiode into information readable for the MARK V Gas Turbine control system. This allows you to get more accurate information about the quality of the combustion as well as the health of your gas turbine.

All of the parts are compatible with one another making it beneficial to purchase as a set. They come all packed together, are easy to assemble and the risk of having missed an important part is eliminated.

Depending on the manufacturer of the junction box, an adapter converting 3/8" to 1/2 ", 3/4" or 1 " may be necessary and is included in the set.

This set includes:

1x Conversion Module with detachable front display   ITS 184X0251M521  ⇨

1x Stainless Steel 90° connector with cable  ITS 184X0251M421  ⇨

1x Spirally-wound metal protective conduit (3 Meter)  ITS 184X0251M461  ⇨

1x Fitting set (consisting of 2 parts)  ITS 184X0251M481  ⇨

1x Junction box fitting set  ITS 184X0251M482  ⇨

1x Flame Scanner  ITS 184X0254M029  ⇨

Documents

PDF Icon   Technical specification Flame Scanner Set Conversion ITS 184X0251M961 (0,5 MB)

Videos and Tutorials

Video Icon   Video Tutorial - Flame Scanner system change UV to SiC on MarkV Turbine Control System on a Gas Turbine

ITS 184X0251M981 Flame Scanner Set - Conversion Premium

ITS 184X0251M981 Flame Scanner Set - Conversion Premium and ITS Flame Scanner 184X0254M-SeriesThe advantage of taking our all inclusive package lies in the fact that all of the pieces fit effortlessly together as they are literally manufactured from one another.

With this set you have done everything you possibly can to bring your Flame Scanning System up to date with the latest technology.

Depending on the manufacturer of the junction box, an adapter converting 3/8" to 1/2 ", 3/4" or 1 " may be necessary and is included in the set.

This set includes:

1x Conversion Module with detachable front display   ITS 184X0251M521  ⇨

1x Stainless Steel 90° connector with cable  ITS 184X0251M421  ⇨

1x Spirally-wound metal protective conduit (3 Meter)  ITS 184X0251M461  ⇨

1x Fitting set (consisting of 2 parts)  ITS 184X0251M481  ⇨

1x Junction box fitting set  ITS 184X0251M482  ⇨

1x Water Cooling Coil  ITS 184X0251M621  ⇨

1x Flame Scanner  ITS 184X0254M029  ⇨

Documents

PDF Icon   Technical specification Flame Scanner Set Conversion Premium ITS 184X0251M981 (0,6 MB)

Accessory Parts for the Flame Scanner ITS 184X0254M-Series    Accessory Parts Icon

Comprehensive expansion of the operational spectrum - A wide range of accessories expands the possibilities to use this Flame Scanner. We have developed a Water Cooling System which can expand the operational temperature range of the Flame Scanner. It consists of a Water Cooling Coil, which prevents the electronics in the Flame Scanner to exceed its temperature limit.

For the Flame Scanner Cable, which is the linkage between the Flame Scanner and the Junction Box, is a Protection System available. It consists of a metal hose and a stainless steel connector.

View details

Purchase ITS flame scanner sets

If you would like to purchase ITS flame scanner sets, please do not hesitate to send a quote request.

Please give us the following information:

> Product ID & number of pieces

> Full business credentials


We are looking forward to sending you a suitable offer as soon as possible.

Send request now